Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Res Int ; 2015: 256340, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25685775

RESUMO

The aim of this research was to analyze temporal auditory processing and phonological awareness in school-age children with benign childhood epilepsy with centrotemporal spikes (BECTS). Patient group (GI) consisted of 13 children diagnosed with BECTS. Control group (GII) consisted of 17 healthy children. After neurological and peripheral audiological assessment, children underwent a behavioral auditory evaluation and phonological awareness assessment. The procedures applied were: Gaps-in-Noise test (GIN), Duration Pattern test, and Phonological Awareness test (PCF). Results were compared between the groups and a correlation analysis was performed between temporal tasks and phonological awareness performance. GII performed significantly better than the children with BECTS (GI) in both GIN and Duration Pattern test (P < 0.001). GI performed significantly worse in all of the 4 categories of phonological awareness assessed: syllabic (P = 0.001), phonemic (P = 0.006), rhyme (P = 0.015) and alliteration (P = 0.010). Statistical analysis showed a significant positive correlation between the phonological awareness assessment and Duration Pattern test (P < 0.001). From the analysis of the results, it was concluded that children with BECTS may have difficulties in temporal resolution, temporal ordering, and phonological awareness skills. A correlation was observed between auditory temporal processing and phonological awareness in the suited sample.


Assuntos
Percepção Auditiva , Conscientização , Epilepsia Rolândica/fisiopatologia , Adolescente , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Estudos Prospectivos
2.
Int J Pharm ; 353(1-2): 170-5, 2008 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-18207677

RESUMO

Plasma is an innovative sterilization method characterized by a low toxicity to operators and patients, and also by its operation at temperatures close to room temperatures. The use of different parameters for this method of sterilization and the corresponding results were analyzed in this study. A low-pressure inductive discharge was used to study the plasma sterilization processes. Oxygen and a mixture of oxygen and hydrogen peroxide were used as plasma source gases. The efficacy of the processes using different combinations of parameters such as plasma-generation method, type of gas, pressure, gas flow rate, temperature, power, and exposure time was evaluated. Two phases were developed for the processes, one using pure oxygen and the other a mixture of gases. Bacillus subtilis var. niger ATCC 9372 (Bacillus atrophaeus) spores inoculated on glass coverslips were used as biological indicators to evaluate the efficacy of the processes. All cycles were carried out in triplicate for different sublethal exposure times to calculate the D value by the enumeration method. The pour-plate technique was used to quantify the spores. D values of between 8 and 3 min were obtained. Best results were achieved at high power levels (350 and 400 W) using pure oxygen, showing that plasma sterilization is a promising alternative to other sterilization methods.


Assuntos
Peróxido de Hidrogênio/farmacologia , Oxigênio/farmacologia , Esterilização/métodos , Bacillus subtilis/efeitos dos fármacos , Plasma , Esporos Bacterianos/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...